Search > Results

You searched for: EV130150 (EV-TRACK ID)

Showing 1 - 2 of 2

Experiment number
  • If needed, multiple experiments were identified in a single publication based on differing sample types, separation protocols and/or vesicle types of interest.
Species
  • Species of origin of the EVs.
Separation protocol
  • Gives a short, non-chronological overview of the different steps of the separation protocol.
    • (d)(U)C = (differential) (ultra)centrifugation
    • DG = density gradient
    • UF = ultrafiltration
    • SEC = size-exclusion chromatography
    • IAF = immuno-affinity capture
Experiment number
  • Experiments differ in Sample type
Experiment number
  • Experiments differ in Sample type
Details EV-TRACK ID Experiment nr. Species Sample type Separation protocol First author Year EV-METRIC
EV130150 1/2 Homo sapiens NAY (d)(U)C Wu Y 2013 14%

Study summary

Full title
All authors
Wu Y, Kwak KJ, Agarwal K, Marras A, Wang C, Mao Y, Huang X, Ma J, Yu B, Lee R, Vachani A, Marcucci G, Byrd JC, Muthusamy N, Otterson G, Huang K, Castro CE, Paulaitis M, Nana-Sinkam SP, Lee LJ
Journal
Anal Chem
Abstract
Noninvasive early detection methods have the potential to reduce mortality rates of both cancer and (show more...)Noninvasive early detection methods have the potential to reduce mortality rates of both cancer and infectious diseases. Here, we present a novel assay by which tethered cationic lipoplex nanoparticles containing molecular beacons (MBs) can capture cancer cell-derived exosomes or viruses and identify encapsulated RNAs in a single step. A series of ultracentrifugation and Exoquick isolation kit were first used to isolate exosomes from the cell culture medium and human serum, respectively. Cationic lipoplex nanoparticles linked onto the surface of a thin glass plate capture negatively charged viruses or cell-secreted exosomes by electrostatic interactions to form larger nanoscale complexes. Lipoplex/virus or lipoplex/exosome fusion leads to the mixing of viral/exosomal RNAs and MBs within the lipoplexes. After the target RNAs specially bind to the MBs, exosomes enriched in target RNAs are readily identified by the fluorescence signals of MBs. The in situ detection of target extracellular RNAs without diluting the samples leads to high detection sensitivity not achievable by existing methods, e.g., quantitative reverse transcription-polymerase chain reaction (qRT-PCR). Here we demonstrate this concept using lentivirus and serum from lung cancer patients. (hide)
EV-METRIC
14% (44th percentile of all experiments on the same sample type)
 Reported
 Not reported
 Not applicable
EV-enriched proteins
Protein analysis: analysis of three or more EV-enriched proteins
non EV-enriched protein
Protein analysis: assessment of a non-EV-enriched protein
qualitative and quantitative analysis
Particle analysis: implementation of both qualitative and quantitative methods. For the quantitative method, the reporting of measured EV concentration is expected.
electron microscopy images
Particle analysis: inclusion of a widefield and close-up electron microscopy image
density gradient
Separation method: density gradient, at least as validation of results attributed to EVs
EV density
Separation method: reporting of obtained EV density
ultracentrifugation specifics
Separation method: reporting of g-forces, duration and rotor type of ultracentrifugation steps
antibody specifics
Protein analysis: antibody clone/reference number and dilution
lysate preparation
Protein analysis: lysis buffer composition
Study data
Sample type
Cell culture supernatant
Sample origin
NAY
Focus vesicles
Separation protocol
Separation protocol
  • Gives a short, non-chronological overview of the
    different steps of the separation protocol.
    • dUC = (Differential) (ultra)centrifugation
    • DG = density gradient
    • UF = ultrafiltration
    • SEC = size-exclusion chromatography
    • IAF = immuno-affinity capture
(d)(U)C
Protein markers
EV:
non-EV:
Proteomics
no
Show all info
Study aim
Technical
Sample
Species
Homo sapiens
Sample Type
Cell culture supernatant
EV-harvesting Medium
serum free
Separation Method
(Differential) (ultra)centrifugation
dUC: centrifugation steps
Between 800 g and 10,000 g
Between 10,000 g and 50,000 g
Between 100,000 g and 150,000 g
Pelleting performed
Yes
Pelleting: time(min)
70
Characterization: Particle analysis
DLS
EM
EM-type
cryo EM
Image type
Close-up
EV130150 2/2 Homo sapiens Serum ExoQuick Wu Y 2013 0%

Study summary

Full title
All authors
Wu Y, Kwak KJ, Agarwal K, Marras A, Wang C, Mao Y, Huang X, Ma J, Yu B, Lee R, Vachani A, Marcucci G, Byrd JC, Muthusamy N, Otterson G, Huang K, Castro CE, Paulaitis M, Nana-Sinkam SP, Lee LJ
Journal
Anal Chem
Abstract
Noninvasive early detection methods have the potential to reduce mortality rates of both cancer and (show more...)Noninvasive early detection methods have the potential to reduce mortality rates of both cancer and infectious diseases. Here, we present a novel assay by which tethered cationic lipoplex nanoparticles containing molecular beacons (MBs) can capture cancer cell-derived exosomes or viruses and identify encapsulated RNAs in a single step. A series of ultracentrifugation and Exoquick isolation kit were first used to isolate exosomes from the cell culture medium and human serum, respectively. Cationic lipoplex nanoparticles linked onto the surface of a thin glass plate capture negatively charged viruses or cell-secreted exosomes by electrostatic interactions to form larger nanoscale complexes. Lipoplex/virus or lipoplex/exosome fusion leads to the mixing of viral/exosomal RNAs and MBs within the lipoplexes. After the target RNAs specially bind to the MBs, exosomes enriched in target RNAs are readily identified by the fluorescence signals of MBs. The in situ detection of target extracellular RNAs without diluting the samples leads to high detection sensitivity not achievable by existing methods, e.g., quantitative reverse transcription-polymerase chain reaction (qRT-PCR). Here we demonstrate this concept using lentivirus and serum from lung cancer patients. (hide)
EV-METRIC
0% (median: 13% of all experiments on the same sample type)
 Reported
 Not reported
 Not applicable
EV-enriched proteins
Protein analysis: analysis of three or more EV-enriched proteins
non EV-enriched protein
Protein analysis: assessment of a non-EV-enriched protein
qualitative and quantitative analysis
Particle analysis: implementation of both qualitative and quantitative methods. For the quantitative method, the reporting of measured EV concentration is expected.
electron microscopy images
Particle analysis: inclusion of a widefield and close-up electron microscopy image
density gradient
Separation method: density gradient, at least as validation of results attributed to EVs
EV density
Separation method: reporting of obtained EV density
ultracentrifugation specifics
Separation method: reporting of g-forces, duration and rotor type of ultracentrifugation steps
antibody specifics
Protein analysis: antibody clone/reference number and dilution
lysate preparation
Protein analysis: lysis buffer composition
Study data
Sample type
Serum
Sample origin
NAY
Focus vesicles
Separation protocol
Separation protocol
  • Gives a short, non-chronological overview of the
    different steps of the separation protocol.
    • dUC = (Differential) (ultra)centrifugation
    • DG = density gradient
    • UF = ultrafiltration
    • SEC = size-exclusion chromatography
    • IAF = immuno-affinity capture
ExoQuick
Protein markers
EV:
non-EV:
Proteomics
no
Show all info
Study aim
Technical
Sample
Species
Homo sapiens
Sample Type
Serum
Separation Method
Commercial kit
ExoQuick
Other
Name other separation method
ExoQuick
Characterization: Particle analysis
EM
EM-type
cryo EM
Image type
Close-up
1 - 2 of 2
  • CM = Commercial method
  • dUC = differential ultracentrifugation
  • DG = density gradient
  • UF = ultrafiltration
  • SEC = size-exclusion chromatography
EV-TRACK ID
EV130150
species
Homo sapiens
sample type
Cell culture
Serum
cell type
NAY
NA
medium
serum free
condition
NAY
NAY
separation protocol
(d)(U)C
ExoQuick
Exp. nr.
1
2
EV-METRIC %
14
0