Search > Results

You searched for: EV170005 (EV-TRACK ID)

Showing 1 - 4 of 4

Experiment number
  • If needed, multiple experiments were identified in a single publication based on differing sample types, separation protocols and/or vesicle types of interest.
Species
  • Species of origin of the EVs.
Separation protocol
  • Gives a short, non-chronological overview of the different steps of the separation protocol.
    • (d)(U)C = (differential) (ultra)centrifugation
    • DG = density gradient
    • UF = ultrafiltration
    • SEC = size-exclusion chromatography
    • IAF = immuno-affinity capture
Details EV-TRACK ID Experiment nr. Species Sample type Separation protocol First author Year EV-METRIC
EV170005 1/4 Homo sapiens SK-MEL103 (d)(U)C
SEC
UF
Suárez H 2017 28%

Study summary

Full title
All authors
Suárez H, Gámez-Valero A, Reyes R, López-Martín S, Rodríguez MJ, Carrascosa JL, Cabañas C, Borràs FE, Yáñez-Mó M
Journal
Sci Rep
Abstract
Most experimental approaches commonly employed for the characterization and quantitation of EVs are (show more...)Most experimental approaches commonly employed for the characterization and quantitation of EVs are time consuming, require of specialized instrumentation and often are rather inaccurate. To circumvent the caveats imposed by EV small size, we used general and specific membrane markers in bead assisted flow cytometry, to provide a semi-quantitative measure of EV content in a given sample. EVs were isolated from in vitro cultured cells-conditioned medium and biological fluids by size exclusion chromatography and coupled to latex beads to allow their detection by standard flow cytometers. Our analyses demonstrate a linear correlation between EV concentration and Mean Fluorescence Intensity values in samples cleared of protein contaminants. Comparison with one of the most widespread method such as NTA, suggests a similar linear range and reliable accuracy to detect saturation. However, although detection of the different biomarkers is feasible when tested on ultracentrifugation-enriched samples, protein contamination impairs quantitation of this type of samples by bead-based flow cytometry. Thus, we provide evidence that bead-assisted flow cytometry method is an accurate and reliable method for the semiquantitative bulk analysis of EVs, which could be easily implemented in most laboratories. (hide)
EV-METRIC
28% (65th percentile of all experiments on the same sample type)
 Reported
 Not reported
 Not applicable
EV-enriched proteins
Protein analysis: analysis of three or more EV-enriched proteins
non EV-enriched protein
Protein analysis: assessment of a non-EV-enriched protein
qualitative and quantitative analysis
Particle analysis: implementation of both qualitative and quantitative methods. For the quantitative method, the reporting of measured EV concentration is expected.
electron microscopy images
Particle analysis: inclusion of a widefield and close-up electron microscopy image
density gradient
Separation method: density gradient, at least as validation of results attributed to EVs
EV density
Separation method: reporting of obtained EV density
ultracentrifugation specifics
Separation method: reporting of g-forces, duration and rotor type of ultracentrifugation steps
antibody specifics
Protein analysis: antibody clone/reference number and dilution
lysate preparation
Protein analysis: lysis buffer composition
Study data
Sample type
Cell culture supernatant
Sample origin
Control condition
Focus vesicles
extracellular vesicle
Separation protocol
Separation protocol
  • Gives a short, non-chronological overview of the
    different steps of the separation protocol.
    • dUC = (Differential) (ultra)centrifugation
    • DG = density gradient
    • UF = ultrafiltration
    • SEC = size-exclusion chromatography
    • IAF = immuno-affinity capture
(d)(U)C
SEC
UF
Protein markers
EV: CD81/ CD59/ CD63/ CD9/ MHC1
non-EV: None
Proteomics
no
Show all info
Study aim
New methodological development
Sample
Species
Homo sapiens
Sample Type
Cell culture supernatant
EV-producing cells
SK-MEL103
EV-harvesting Medium
EV-depleted serum
Preparation of EDS
overnight (16h) at >=100,000g
Separation Method
(Differential) (ultra)centrifugation
dUC: centrifugation steps
Below or equal to 800 g
Between 800 g and 10,000 g
Pelleting performed
No
Ultra filtration
Cut-off size (kDa)
Not spec
Membrane type
Not specified
Size-exclusion chromatography
Total column volume (mL)
20
Sample volume/column (mL)
1.5
Resin type
Sepharose CL-2B
Characterization: Protein analysis
Protein Concentration Method
BCA
Protein Yield (µg)
148.16
Characterization: Lipid analysis
No
Characterization: Particle analysis
NTA
Report type
Median
EV170005 4/4 Homo sapiens Primary T-lymphoblasts (d)(U)C
SEC
UF
Suárez H 2017 28%

Study summary

Full title
All authors
Suárez H, Gámez-Valero A, Reyes R, López-Martín S, Rodríguez MJ, Carrascosa JL, Cabañas C, Borràs FE, Yáñez-Mó M
Journal
Sci Rep
Abstract
Most experimental approaches commonly employed for the characterization and quantitation of EVs are (show more...)Most experimental approaches commonly employed for the characterization and quantitation of EVs are time consuming, require of specialized instrumentation and often are rather inaccurate. To circumvent the caveats imposed by EV small size, we used general and specific membrane markers in bead assisted flow cytometry, to provide a semi-quantitative measure of EV content in a given sample. EVs were isolated from in vitro cultured cells-conditioned medium and biological fluids by size exclusion chromatography and coupled to latex beads to allow their detection by standard flow cytometers. Our analyses demonstrate a linear correlation between EV concentration and Mean Fluorescence Intensity values in samples cleared of protein contaminants. Comparison with one of the most widespread method such as NTA, suggests a similar linear range and reliable accuracy to detect saturation. However, although detection of the different biomarkers is feasible when tested on ultracentrifugation-enriched samples, protein contamination impairs quantitation of this type of samples by bead-based flow cytometry. Thus, we provide evidence that bead-assisted flow cytometry method is an accurate and reliable method for the semiquantitative bulk analysis of EVs, which could be easily implemented in most laboratories. (hide)
EV-METRIC
28% (65th percentile of all experiments on the same sample type)
 Reported
 Not reported
 Not applicable
EV-enriched proteins
Protein analysis: analysis of three or more EV-enriched proteins
non EV-enriched protein
Protein analysis: assessment of a non-EV-enriched protein
qualitative and quantitative analysis
Particle analysis: implementation of both qualitative and quantitative methods. For the quantitative method, the reporting of measured EV concentration is expected.
electron microscopy images
Particle analysis: inclusion of a widefield and close-up electron microscopy image
density gradient
Separation method: density gradient, at least as validation of results attributed to EVs
EV density
Separation method: reporting of obtained EV density
ultracentrifugation specifics
Separation method: reporting of g-forces, duration and rotor type of ultracentrifugation steps
antibody specifics
Protein analysis: antibody clone/reference number and dilution
lysate preparation
Protein analysis: lysis buffer composition
Study data
Sample type
Cell culture supernatant
Sample origin
Control condition
Focus vesicles
extracellular vesicle
Separation protocol
Separation protocol
  • Gives a short, non-chronological overview of the
    different steps of the separation protocol.
    • dUC = (Differential) (ultra)centrifugation
    • DG = density gradient
    • UF = ultrafiltration
    • SEC = size-exclusion chromatography
    • IAF = immuno-affinity capture
(d)(U)C
SEC
UF
Protein markers
EV: CD81/ CD59/ CD63/ CD9/ MHC1
non-EV: None
Proteomics
no
Show all info
Study aim
New methodological development
Sample
Species
Homo sapiens
Sample Type
Cell culture supernatant
EV-producing cells
Primary T-lymphoblasts
EV-harvesting Medium
EV-depleted serum
Preparation of EDS
overnight (16h) at >=100,000g
Separation Method
(Differential) (ultra)centrifugation
dUC: centrifugation steps
Below or equal to 800 g
Between 800 g and 10,000 g
Pelleting performed
No
Ultra filtration
Cut-off size (kDa)
Not spec
Membrane type
Not specified
Size-exclusion chromatography
Total column volume (mL)
20
Sample volume/column (mL)
1.5
Resin type
Sepharose CL-2B
Characterization: Protein analysis
Protein Concentration Method
BCA
Protein Yield (µg)
116.85
Characterization: Lipid analysis
No
Characterization: Particle analysis
NTA
Report type
Median
EV170005 3/4 Homo sapiens SK-MEL103 (d)(U)C Suárez H 2017 25%

Study summary

Full title
All authors
Suárez H, Gámez-Valero A, Reyes R, López-Martín S, Rodríguez MJ, Carrascosa JL, Cabañas C, Borràs FE, Yáñez-Mó M
Journal
Sci Rep
Abstract
Most experimental approaches commonly employed for the characterization and quantitation of EVs are (show more...)Most experimental approaches commonly employed for the characterization and quantitation of EVs are time consuming, require of specialized instrumentation and often are rather inaccurate. To circumvent the caveats imposed by EV small size, we used general and specific membrane markers in bead assisted flow cytometry, to provide a semi-quantitative measure of EV content in a given sample. EVs were isolated from in vitro cultured cells-conditioned medium and biological fluids by size exclusion chromatography and coupled to latex beads to allow their detection by standard flow cytometers. Our analyses demonstrate a linear correlation between EV concentration and Mean Fluorescence Intensity values in samples cleared of protein contaminants. Comparison with one of the most widespread method such as NTA, suggests a similar linear range and reliable accuracy to detect saturation. However, although detection of the different biomarkers is feasible when tested on ultracentrifugation-enriched samples, protein contamination impairs quantitation of this type of samples by bead-based flow cytometry. Thus, we provide evidence that bead-assisted flow cytometry method is an accurate and reliable method for the semiquantitative bulk analysis of EVs, which could be easily implemented in most laboratories. (hide)
EV-METRIC
25% (64th percentile of all experiments on the same sample type)
 Reported
 Not reported
 Not applicable
EV-enriched proteins
Protein analysis: analysis of three or more EV-enriched proteins
non EV-enriched protein
Protein analysis: assessment of a non-EV-enriched protein
qualitative and quantitative analysis
Particle analysis: implementation of both qualitative and quantitative methods. For the quantitative method, the reporting of measured EV concentration is expected.
electron microscopy images
Particle analysis: inclusion of a widefield and close-up electron microscopy image
density gradient
Separation method: density gradient, at least as validation of results attributed to EVs
EV density
Separation method: reporting of obtained EV density
ultracentrifugation specifics
Separation method: reporting of g-forces, duration and rotor type of ultracentrifugation steps
antibody specifics
Protein analysis: antibody clone/reference number and dilution
lysate preparation
Protein analysis: lysis buffer composition
Study data
Sample type
Cell culture supernatant
Sample origin
Control condition
Focus vesicles
extracellular vesicle
Separation protocol
Separation protocol
  • Gives a short, non-chronological overview of the
    different steps of the separation protocol.
    • dUC = (Differential) (ultra)centrifugation
    • DG = density gradient
    • UF = ultrafiltration
    • SEC = size-exclusion chromatography
    • IAF = immuno-affinity capture
(d)(U)C
Adj. k-factor
264.9 (pelleting) / 264.9 (washing)
Protein markers
EV: CD59/ CD9
non-EV: None
Proteomics
no
Show all info
Study aim
New methodological development
Sample
Species
Homo sapiens
Sample Type
Cell culture supernatant
EV-producing cells
SK-MEL103
EV-harvesting Medium
EV-depleted serum
Preparation of EDS
overnight (16h) at >=100,000g
Separation Method
(Differential) (ultra)centrifugation
dUC: centrifugation steps
Below or equal to 800 g
Between 800 g and 10,000 g
Between 10,000 g and 50,000 g
Between 100,000 g and 150,000 g
Pelleting performed
Yes
Pelleting: time(min)
120
Pelleting: rotor type
AH-627
Pelleting: speed (g)
100000
Pelleting: adjusted k-factor
264.9
Wash: time (min)
120
Wash: Rotor Type
AH-627
Wash: speed (g)
100000
Wash: adjusted k-factor
264.9
Characterization: Protein analysis
Protein Concentration Method
BCA
Characterization: Lipid analysis
No
Characterization: Particle analysis
NTA
Report type
Median
EV170005 2/4 Homo sapiens Urine (d)(U)C
SEC
UF
Suárez H 2017 14%

Study summary

Full title
All authors
Suárez H, Gámez-Valero A, Reyes R, López-Martín S, Rodríguez MJ, Carrascosa JL, Cabañas C, Borràs FE, Yáñez-Mó M
Journal
Sci Rep
Abstract
Most experimental approaches commonly employed for the characterization and quantitation of EVs are (show more...)Most experimental approaches commonly employed for the characterization and quantitation of EVs are time consuming, require of specialized instrumentation and often are rather inaccurate. To circumvent the caveats imposed by EV small size, we used general and specific membrane markers in bead assisted flow cytometry, to provide a semi-quantitative measure of EV content in a given sample. EVs were isolated from in vitro cultured cells-conditioned medium and biological fluids by size exclusion chromatography and coupled to latex beads to allow their detection by standard flow cytometers. Our analyses demonstrate a linear correlation between EV concentration and Mean Fluorescence Intensity values in samples cleared of protein contaminants. Comparison with one of the most widespread method such as NTA, suggests a similar linear range and reliable accuracy to detect saturation. However, although detection of the different biomarkers is feasible when tested on ultracentrifugation-enriched samples, protein contamination impairs quantitation of this type of samples by bead-based flow cytometry. Thus, we provide evidence that bead-assisted flow cytometry method is an accurate and reliable method for the semiquantitative bulk analysis of EVs, which could be easily implemented in most laboratories. (hide)
EV-METRIC
14% (40th percentile of all experiments on the same sample type)
 Reported
 Not reported
 Not applicable
EV-enriched proteins
Protein analysis: analysis of three or more EV-enriched proteins
non EV-enriched protein
Protein analysis: assessment of a non-EV-enriched protein
qualitative and quantitative analysis
Particle analysis: implementation of both qualitative and quantitative methods. For the quantitative method, the reporting of measured EV concentration is expected.
electron microscopy images
Particle analysis: inclusion of a widefield and close-up electron microscopy image
density gradient
Separation method: density gradient, at least as validation of results attributed to EVs
EV density
Separation method: reporting of obtained EV density
ultracentrifugation specifics
Separation method: reporting of g-forces, duration and rotor type of ultracentrifugation steps
antibody specifics
Protein analysis: antibody clone/reference number and dilution
lysate preparation
Protein analysis: lysis buffer composition
Study data
Sample type
Urine
Sample origin
Control condition
Focus vesicles
extracellular vesicle
Separation protocol
Separation protocol
  • Gives a short, non-chronological overview of the
    different steps of the separation protocol.
    • dUC = (Differential) (ultra)centrifugation
    • DG = density gradient
    • UF = ultrafiltration
    • SEC = size-exclusion chromatography
    • IAF = immuno-affinity capture
(d)(U)C
SEC
UF
Protein markers
EV: CD63/ CD9
non-EV: None
Proteomics
no
Show all info
Study aim
New methodological development
Sample
Species
Homo sapiens
Sample Type
Urine
Separation Method
(Differential) (ultra)centrifugation
dUC: centrifugation steps
Below or equal to 800 g
Between 800 g and 10,000 g
Pelleting performed
No
Ultra filtration
Cut-off size (kDa)
Not spec
Membrane type
Not specified
Size-exclusion chromatography
Total column volume (mL)
20
Sample volume/column (mL)
1.5
Resin type
Sepharose CL-2B
Characterization: Protein analysis
Protein Concentration Method
BCA
Characterization: Lipid analysis
No
1 - 4 of 4
  • CM = Commercial method
  • dUC = differential ultracentrifugation
  • DG = density gradient
  • UF = ultrafiltration
  • SEC = size-exclusion chromatography
EV-TRACK ID
EV170005
species
Homo sapiens
sample type
Cell culture
Cell culture
Cell culture
Urine
cell type
SK-MEL103
Primary
T-lymphoblasts
SK-MEL103
NA
medium
EV-depleted serum
EV-depleted serum
EV-depleted serum
NA
condition
Control condition
Control condition
Control condition
Control condition
separation protocol
(d)(U)C
SEC
UF
(d)(U)C
SEC
UF
(d)(U)C
(d)(U)C
SEC
UF
Exp. nr.
1
4
3
2
EV-METRIC %
28
28
25
14